Internal pipe corrosion: causes, warning signs and how to prevent it
2 min readRoyal Integrity technical team

Internal corrosion is silent: it advances inside the pipeline, out of sight, until it shows up as a leak, a pressure loss or a spill. In Oil & Gas it is one of the main threats to the integrity of flowlines, oil pipelines, gas pipelines and produced water systems. According to NACE’s IMPACT study (2016), corrosion costs the world about US$2.5 trillion a year, and applying good control practices could save between 15% and 35% of that cost.
The most common causes
- CO₂ (sweet) corrosion: CO₂ dissolved in water forms carbonic acid that attacks carbon steel.
- H₂S (sour) corrosion: it causes pitting and can lead to cracking of the steel.
- Microbiologically influenced corrosion (MIC): bacteria, such as sulfate-reducing bacteria, create aggressive environments under their colonies.
- Under-deposit corrosion: sand, paraffins, scale and sludge trap water and bacteria against the wall.
- Water accumulated at low points: where the flow does not sweep the water away, corrosion concentrates.
- Erosion-corrosion: high velocities with solids remove the metal’s protective layer.
Warning signs
- Rising iron content in the fluid.
- Wall thickness loss in ultrasonic measurements or inspection runs.
- Corrosion coupons or probes showing increasing rates.
- Pressure drops or flow restrictions caused by deposits.
- Black solids (iron sulfide) when pigs are received.
How to prevent it: a layered strategy
- Periodic mechanical cleaning (pigging): removes the water, solids and deposits that feed corrosion. Without cleaning, no inhibitor reaches the pipe wall.
- Corrosion inhibitors dosed according to the fluid and conditions.
- Water control through dehydration and good operating practices.
- Monitoring with coupons, probes and in-line inspection.
- Preservation of out-of-service lines with volatile corrosion inhibitors (VCI) to keep corrosion from advancing during shutdowns.
The difference the data shows
In measurements published by Royal Integrity, the corrosion rate goes from 0.19 MPY untreated to 0.0075 MPY with its control program. That difference translates into additional years of service life and fewer interventions.
The Royal Integrity approach
Royal Integrity integrates line cleaning, gauging and isolation with iNPIPE Products, Zerust/Excor VCI inhibitors and its Asset Preservation Program, with field technical support and after-sales follow-up.
Frequently asked questions
What is MPY? Mils per year (thousandths of an inch per year), the most widely used unit for expressing corrosion rate.
How often should a cleaning pig be run? It depends on the fluid, water and solids; it is defined from monitoring and the line’s history.
Does cathodic protection prevent internal corrosion? No. Cathodic protection protects the outside of the pipeline; the inside requires cleaning, inhibition and monitoring.